PRESSCONTROL WATERTECH DA 1,5

€ 50.00

Warning: Last items in stock!

ELECTRONIC PUMP REGULATOR the height of the water column max is 15 meters, the minimum pressure of the pump must be 30 meters. pressure max 10 atm. power supply 220v frequency 50-60 hz max power 1.5 kw (2cv) protection rating IP65 male connections 1 '' max. 65 C °. product designed and built in ITALY

Write your review

PRESSCONTROL WATERTECH DA 1,5

PRESSCONTROL WATERTECH DA 1,5

ELECTRONIC PUMP REGULATOR the height of the water column max is 15 meters, the minimum pressure of the pump must be 30 meters. pressure max 10 atm. power supply 220v frequency 50-60 hz max power 1.5 kw (2cv) protection rating IP65 male connections 1 '' max. 65 C °. product designed and built in ITALY

Write your review

Summary

  • Product Name:PRESSCONTROL WATERTECH DA 1,5
  • Price: 50.00
  • Product Width: 0.00 cm
  • Product Height: 0.00 cm
  • Product Depth: 0.00 cm
  • Product Weight: 2.00 kg
  • Description: ELECTRONIC PUMP REGULATOR the height of the water column max is 15 meters, the minimum pressure of the pump must be 30 meters. pressure max 10 atm. power supply 220v frequency 50-60 hz max power 1.5 kw (2cv) protection rating IP65 male connections 1 '' max. 65 C °. product designed and built in ITALY
Path: > > PRESSCONTROL WATERTECH DA 1,5

Ask a question

NO registration required!

3 Question(s) answered

If the question you have has not yet been answered here, use the form below to ask something about this addon.

(optional)
*(Required to be notified when an answer is available)
  • Asked by draranti francesco
    on 03/13/2019
    attacca e stacca ogni 15 secondi ad rubinetti chiusi- come arriva a 2,5 scende piano piano sino a 2 e attaccala pompa- vorrei sapere cosa devo fare- grazie! Answer:
    buongiorno , questo sntomo è dovuto ad un abbassamento di pressione per qualche perdita , controlli la cassetta del bagno che spesso sono la causa di questo . se quando hanno installato il presscontrol hanno ontato una valvola di chiusura subito dopo l'apparecchio la chiuda e vede se scende la pressione in modo da escludere l'apparecchio
  • Asked by Luciano
    on 03/16/2020
    Buonasera! La pressione minima della pompa deve essere minimo 30 mt. a cosa si riferisce? Forse alla portata in litri al min? Tutto il resto rientra nel mio caso : pompa da 1,5 hp(1,1 kw) altezza montaggio dispositivo: pochi cm. Portata fino max 70 litri min. grazie Answer:
  • Asked by Alan Speight
    on 06/07/2023
    What are common faults Answer: